The CAN specialist
-Hidden- -Hidden-
Nederlandse taal English language
Skip to main content

PCAN-Ethernet Gateway DR

CAN Ethernet gateway and PC interface with 2x CAN, galvanic isolation

On request

 

 
 
The Peak PCAN-Ethernet Gateway DR supports the CAN protocol
PCAN-Ethernet Gateway DRby Peak

Stock DE

Request for quote

Ask a question

The Peak PCAN-Ethernet Gateway DR enables multiple CAN buses to be connected via IP networks. CAN frames are encapsulated in TCP or UDP packets. The data is then forwarded to other devices via the IP network. Furthermore, the gateway features one LAN port and two high-speed CAN interfaces. This provides a flexible solution for industrial communication.

Furthermore, the Peak PCAN-Ethernet Gateway DR offers extensive configuration options. Filter functions and routing rules are available for targeted data processing. This allows data traffic to be efficiently managed and optimised, for example in complex industrial networks with multiple CAN segments. Furthermore, this helps to reduce network load. Consequently, the gateway is suitable for demanding applications. Even during intensive communication, data transfer remains clear and reliable.

The PCAN Gateway product family is primarily configured via a user-friendly web interface. Access is also possible via the JSON interface for software integration. Both options provide comprehensive status information and configuration settings. Furthermore, they support the management of communication interfaces, filters and message forwarding. This allows systems to be flexibly adapted to specific applications. In short, the PCAN-Ethernet Gateway DR combines reliable CAN communication with modern networking functionality.

The PCAN-Ethernet Gateway DR can also function as a CAN-to-Ethernet gateway. This means that, if required, the system can be installed at a greater distance from a PC. Meanwhile, the Peak PC drivers support this gateway just like any other PC interface. As a result, virtually all available software tools and APIs work seamlessly with the PCAN-Ethernet Gateway DR. In short, this gateway offers a powerful and scalable solution for professional CAN communication.

The PCAN View bus monitor for Windows® is included as standard. This software is suitable for rapid CAN diagnostics, hardware testing, and reading CAN messages. For comprehensive CAN analysis and simulation, there is the PCAN Explorer 7. This professional software supports the development, debugging, logging, and testing of CAN networks. Read the FAQ below for advice on the best CAN analysis software for your specific situation.


Features and benefits

  • Combines 2x CAN in one gateway
  • CAN to CAN or CAN to PC/Server gateway
  • Easy coupling of CAN systems and devices
  • Allows system expansion and tree/star topologies
  • Simplify and optimise CAN networks
  • Increased system reliability
  • Galvanic Isolation between network and gateway
  • CAN communication up to 1 Mbit/s via screw connectors
  • Includes CAN Bus Monitor software for Windows®
  • Universe driver for easy exchange between different Peak interfaces
  • Powerful programming interface for Windows® and Linux (incl. SocketCAN)
  • Cost savings due to simple wiring

Tech Specs

CAN Mode

CAN high-speed (ISO 11898-2)

CAN Baudrates

5 kBit/s … 1 Mbit/s

Ethernet

TCP/IP 10/100 RJ45
1-to-1 auto crossover

IP Adressing

Static (standard)
or DHCP

Galvanic Isolation

Up to 500 V

Connector

Screw

Power Supply

8~30 V=

Current Consumption

max. 100 mA at 30 V=

Temperature

Usage -40 °C to +85 °C
Storage -40 °C to +125 °C

Dimensions

22.5 x 99 x 114.5 mm

Certification

CE, UKCA
 
The following software is provided free of charge with the Peak PCAN-Ethernet Gateway DR. The current version is available for download.

CAN Bus Monitor

Peak PCAN-View

For basic testing purposes and start-up, PCAN-View – a CAN bus monitor for Windows® – is included. The software is installed when the driver package is installed under Windows®.

This monitor can be used to display CAN messages with timestamps, message IDs, and data using PCAN-Ethernet Gateway DR. A trace function allows the received data to be written directly to the hard drive. CAN messages are sent from a list in which the CAN messages have been entered. Installed interfaces are displayed with the available CAN controllers, the current bus load and the controller status. PCAN-View also supports CAN-FD in combination with interfaces that support these protocols.

Common Driver

Peak Device Driver

PCAN is available for the PCAN-Ethernet Gateway DR, which is a synonym for ‘Peak CAN Applications’. This is a flexible system for planning, developing and using Controller Area Networks (CAN). It is a powerful product for both developers and end users.

The PCAN system consists of a collection of Windows® device drivers. These enable a real-time connection between Windows® applications and all CAN buses that are physically connected to the PC via PCAN hardware. These drivers allow all CAN channels and all CAN interfaces – even different types – to work together within a single PC.

These powerful driver packages support all CAN boards, regardless of their PC interface, with a uniform programming interface (API). This means that applications based on the API can be used with all Peak CAN without having to modify the application programme. The drivers support multiple CAN channels and/or multiple boards – even different types – to create the desired number of channels.

Features and benefits

  • Common application programming interface (API) for all supported operating systems and interfaces
  • Simultaneous support of multiple CAN channels and interface boards
  • Classic CAN (11 bit, CAN 2.0A), extended protocol (29 bit, CAN 2.0B), CAN FD and CAN XL1
  • Slim communication interface while supporting all required mechanisms for an easy operation of the interface
  • Detection and display of error frames on the bus
  • Measurement and display of the bus load (only with active CAN cards)
  • Possible operation in "Listen only mode"
  • 1 For interfaces that support these protocols

Programming environment

Programeerinterface "PCAN-Basic"

The PCAN-Basic programming interface (API) provides basic functions for connecting your own programmes to the CAN and CAN FD interfaces from PEAK-System. PCAN-Basic is the interface between the programme and the driver. In Windows® operating systems, this is a DLL (Dynamic Link Library) and in Linux operating systems, it is an SO (Dynamic Shared Object). PCAN-Basic is designed to be compatible with different operating systems. Software projects can be transferred between supported systems with little effort.

When installing the driver under Windows®, the DLL files of the PCAN-Basic API are placed in the system folder. Examples for all common programming languages, as well as libraries and help files, are available as a download package.

 

FAQ

  • Are CAN terminating resistors built into the PCAN-Ethernet Gateway DR?

    Yes, terminating resistors are built in, but they are disabled by default. The termination can be activated using a solder bridge, for each desired CAN-channel, which requires special tools.
    As a convenient alternative, we can offer the Termination adapter CAN/ CAN FD as an accessory. It can be easily installed between the D-sub 9 connector and the cable without any tools, for each desired CAN channel.

  • How do I choose the right CAN gateway?

    Choosing the right CAN gateway depends, among other things, on the desired CAN protocol, the intended application, the desired bus speed and electrical isolation, data processing requirements, the length of the network, the acceptable processing delay, any available installation space, the intended use, and, of course, the available budget.

    Twincomm is a center of expertise for CAN and has over 30 years of experience with CAN. Please contact us and we’ll provide practical advice to help you make the right choice.

  • Which PEAK CAN analysis software is best suited to my use case?

    PCAN View and PCAN Explorer 7 are versatile CAN analysis tools for developing, testing, and maintaining CAN and CAN FD systems. Explorer 7 also supports CAN XL. PCAN View offers a basic set of features, while PCAN Explorer 7 offers more and advanced features that can also be expanded with add-ins.
    PCAN View is included free of charge with the PEAK driver. It is ideal for quick diagnostics or hardware testing, for example. Explorer 7 is comprehensive, professional software designed for development, debugging, simulation, or (automated testing) of CAN, CAN FD, and/or CAN XL networks. Please contact us for a demo version of Explorer 7.

    Zowel PCAN View als PCAN Explorer 7 zijn bedoeld voor een typisch gebruiksscenario. De onderstaande tabel geeft een handig overzicht van alle verschillen.

    Functions Module PCAN View Explorer 7
    Measurement configuration
    Supported bus controllers Channels 1 64
    Supported CAN protocols
    CAN
    CAN FD
    CAN XL
    Channels





    Transmission
    Transmitting messages in layer 2 format via broadcasting lists (one-off/cyclic) Transmit
    Transmitting sequences in layer 2 format to emulate CAN-nodes Transmit  
    Reception and display
    Display received messages
    - Scroll view
    - Overwrite mode
    Receive



    Filtering during reception or recording Filter  
    Symbolic representation via Symbol files Symbol  
    Symbolic aditor Symbol  
    Symbolic import from CANdb Import or AUTOSAR XML CANdb add-in  
    Recording/Playback
    Recording on hard disk
    - Maximum size
    Record
    1 GB

    Filter and trigger functions during recording Filter  
    Playback of recordings on the buses for analyzing Replay  
    Playback break pints and single step Replay  
    Workflow management
    Project and task management Workflow   Phyton
    VBScript
    Automation of tasks Automation   Phyton
    VBScript
    Take actions triggered by CAN Automation   Phyton
    VBScript
    J1939 Support
    Display of J19839 and J1939 FD messages J1939 Add-in  
    Adresclaiming, Multi-packet or DTC's J1939 Add-in  
    Configurable Display of Signal Curves
    Graphical real-time display of signals Plotter Add-in  
    Display of limiting values and value ranges Plotter Add-in  
    Signal Display and Manipulation
    Representation of analog and digital signals with displays Panel Add-in  
    Adding controls to manipulate transmit messages Panel Add-in  
  • Does this gateway support CANopen or J1939?

    Yes, the PCAN-Ethernet Gateway DR works with all CAN messages, including CANopen and J1939

    However, the CAN messages are not interpreted as CANopen or J1939. In filter and mapping tables, or action rules, for example, the messages are treated as standard CAN messages. enquire about the configuration options.

  • Can I order on account?

    Yes, that's definitely possible! Most customers place their orders through a Purchase Order.
    First request a quote and then send the purchase order (PO) by email, simply from your own purchasing system. For first time buyers, we may ask additional questions in order to perform a credit check. Please contact us if you require our company details for registration in the purchasing system.

    For security reasons, customers located in, or wishing to ship to, countries outside the Benelux must always pay in advance.

  • Why are all prices available upon request?

    The online webshop is still under construction. As soon as it is available, all prices will naturally be visible.

    However, everything is of course available, and we would be happy to inform you about prices and delivery times. Please contact us or give us a call. We have over 30 years of experience with CAN. We are happy to help you and offer you immediate practical advice or support.

 

Part number(s)

IPEH-004010 PCAN-Ethernet Gateway DR
2x CAN, Galvanic Isolation
Country of Origin: Germany
HS Code: 9031900000

Scope of Supply

PCAN-Ethernet Gateway DR
  • User Manual 1
  • RJ-45 network patch cord
1 Available as PDF

Interested?

Are you interested in the PCAN-Ethernet Gateway DR? Request a quote without obligation. Would you like more information? Send an email to -Hidden- or visit our contact page. You can also call us at -Hidden-.
Twincomm has over 30 years of experience with CAN. We are happy to help you and offer you immediate practical advice or support.