The CAN specialist
-Hidden- -Hidden-
Nederlandse taal English language
Skip to main content
PCAN-USB X6 D-Sub 9
PCAN-USB X6 M12

PCAN-USB X6

PC USB interface with 6x CAN FD / CAN, galvanic isolation (optional)

On request

 

 
 
The Peak PCAN-USB X6 supports the CAN protocol
The Peak PCAN-USB X6 supports the CAN FD protocol
PCAN-USB X6by Peak

Request for quote

Ask a question

The Peak PCAN-USB X6 is a powerful CAN FD interface for the USB port. It allows up to six CAN FD or CAN buses to be connected simultaneously. This interface is primarily designed for complex CAN networks. In addition, the device supports comprehensive test and development environments. For example, during hardware-in-the-loop simulations in automotive development. This interface also offers significant advantages when testing CAN-based product lines. That is why developers often choose the PCAN-USB X6 for intensive CAN analysis. Furthermore, the high channel density provides additional flexibility during projects involving multiple CAN networks.

The PCAN View bus monitor for Windows® is included as standard. This software is suitable for rapid CAN diagnostics, hardware testing, and reading CAN messages. For comprehensive CAN analysis and simulation, there is the PCAN Explorer 7. This professional software supports the development, debugging, logging, and testing of CAN networks. Read the FAQ below for advice on the best CAN analysis software for your specific situation.

The PCAN-USB X6 also features a robust aluminum profile housing. This makes the interface suitable for intensive daily use. Additionally, the device is available with D-Sub connectors or M12 connectors. The M12 version, in particular, performs exceptionally well in harsh industrial environments. In mobile applications, the connection remains reliable and stable. In short, the PCAN-USB X6 interface combines flexibility, reliability, and professional CAN FD functionality in a single compact design.

The PCAN-USB X6 interface is available in a version with galvanic isolation and a version without, depending on the desired protection and application. Read the FAQ for more information.


Features and benefits

  • Combines 6x CAN FD or CAN in one device
  • Cost-effective, versatile and extremely reliable
  • Accurate timestamp
  • High data throughput
  • Galvanic Isolation between network and device (optional)
  • CAN FD communication up to 12 Mbit/s
  • Includes CAN Bus Monitor software for Windows®
  • Universe driver for easy exchange between different Peak interfaces
  • Powerful programming interface for Windows® and Linux (incl. SocketCAN)

Tech Specs

Controller

6x CAN FD or
CAN CC (Classic CAN 2.0A/B)

CAN FD Mode

ISO CAN FD (ISO 11898-1)
nonISO CAN FD

CAN FD Baudrate

Arbitration 25 kBit/s … 1 Mbit/s
Data rate max 12 MBit/s

CAN FD Transceiver

NXP TJA1044GT

CAN Mode

CAN high-speed (ISO 11898-2)

CAN Baudrates

5 kBit/s … 1 Mbit/s

Galvanic Isolation

Up to 300 V (optional)

Connector

D-Sub9 (CiA® 106)

PC Interface

USB-A

Driver

Peak Device Driver for Windows® or Linux

Power Supply

8~30 V=

Current Consumption

max. 350 mA at 12 V=

Temperature

Usage -40 °C to +85 °C
Storage -40 °C to +100 °C

Dimensions

170 x 93 x 65 mm

Certification

CE, UKCA

Tech Specs (M12)

Galvanic Isolation

Up to 300 V

Connector

M12 (CiA® 106)

PC Interface

USB-B Mini
USB high speed 480 MBit/sec

Dimensions

170 x 103 x 65 mm
 
The following software is provided free of charge with the Peak PCAN-USB X6. The current version is available for download.

CAN Bus Monitor

Peak PCAN-View

For basic testing purposes and start-up, PCAN-View – a CAN bus monitor for Windows® – is included. The software is installed when the driver package is installed under Windows®.

This monitor can be used to display CAN messages with timestamps, message IDs, and data using PCAN-USB X6. A trace function allows the received data to be written directly to the hard drive. CAN messages are sent from a list in which the CAN messages have been entered. Installed interfaces are displayed with the available CAN controllers, the current bus load and the controller status. PCAN-View also supports CAN-FD in combination with interfaces that support these protocols.

Common Driver

Peak Device Driver

PCAN is available for the PCAN-USB X6, which is a synonym for ‘Peak CAN Applications’. This is a flexible system for planning, developing and using Controller Area Networks (CAN). It is a powerful product for both developers and end users.

The PCAN system consists of a collection of Windows® device drivers. These enable a real-time connection between Windows® applications and all CAN buses that are physically connected to the PC via PCAN hardware. These drivers allow all CAN channels and all CAN interfaces – even different types – to work together within a single PC.

These powerful driver packages support all CAN boards, regardless of their PC interface, with a uniform programming interface (API). This means that applications based on the API can be used with all Peak CAN without having to modify the application programme. The drivers support multiple CAN channels and/or multiple boards – even different types – to create the desired number of channels.

Features and benefits

  • Common application programming interface (API) for all supported operating systems and interfaces
  • Simultaneous support of multiple CAN channels and interface boards
  • Classic CAN (11 bit, CAN 2.0A), extended protocol (29 bit, CAN 2.0B), CAN FD and CAN XL1
  • Slim communication interface while supporting all required mechanisms for an easy operation of the interface
  • Detection and display of error frames on the bus
  • Measurement and display of the bus load (only with active CAN cards)
  • Possible operation in "Listen only mode"
  • 1 For interfaces that support these protocols

Programming environment

Programeerinterface "PCAN-Basic"

The PCAN-Basic programming interface (API) provides basic functions for connecting your own programmes to the CAN and CAN FD interfaces from PEAK-System. PCAN-Basic is the interface between the programme and the driver. In Windows® operating systems, this is a DLL (Dynamic Link Library) and in Linux operating systems, it is an SO (Dynamic Shared Object). PCAN-Basic is designed to be compatible with different operating systems. Software projects can be transferred between supported systems with little effort.

When installing the driver under Windows®, the DLL files of the PCAN-Basic API are placed in the system folder. Examples for all common programming languages, as well as libraries and help files, are available as a download package.

 

FAQ

  • Should I choose a CAN interface with or without galvanic isolation?

    A PCAN-USB X6 with galvanic isolation offers improved noise immunity and prevents ground loops. The potential differences caused by separate power supplies for different CAN nodes do not affect transmission quality. In addition, it protects the device from damage to the electronics caused by power surges.
    We generally recommend galvanic isolation.

    However, galvanic isolation reduces the maximum possible CAN bus length by approximately 10 metres (50 ns delay).

    Please note that the CAN_GND is always connected, even when galvanic isolation is used.

  • Are CAN terminating resistors built into the PCAN-USB X6?

    Yes, terminating resistors are built in, but they are disabled by default. The termination can be activated using a solder bridge, for each desired CAN-channel, which requires special tools.
    As a convenient alternative, we can offer the Termination adapter CAN/ CAN FD as an accessory. It can be easily installed between the D-sub 9 connector and the cable without any tools, for each desired CAN channel.

  • How do I choose the right PC to USB interface card?

    Choosing the right USB CAN interface depends, among other things, on the desired CAN protocol, the intended application, the available USB port, the processing speed, the intended use, and, of course, the available budget. Although CAN is standardized, CAN hardware and PC drivers varies by brand. It is important to consider which software or development tools are required before selecting a specific interface.

    Twincomm is a center of expertise for CAN and has over 30 years of experience with CAN. Please contact us and we’ll provide practical advice to help you make the right choice.

  • Which PEAK CAN analysis software is best suited to my use case?

    PCAN View and PCAN Explorer 7 are versatile CAN analysis tools for developing, testing, and maintaining CAN and CAN FD systems. Explorer 7 also supports CAN XL. PCAN View offers a basic set of features, while PCAN Explorer 7 offers more and advanced features that can also be expanded with add-ins.
    PCAN View is included free of charge with the PEAK driver. It is ideal for quick diagnostics or hardware testing, for example. Explorer 7 is comprehensive, professional software designed for development, debugging, simulation, or (automated testing) of CAN, CAN FD, and/or CAN XL networks. Please contact us for a demo version of Explorer 7.

    Zowel PCAN View als PCAN Explorer 7 zijn bedoeld voor een typisch gebruiksscenario. De onderstaande tabel geeft een handig overzicht van alle verschillen.

    Functions Module PCAN View Explorer 7
    Measurement configuration
    Supported bus controllers Channels 1 64
    Supported CAN protocols
    CAN
    CAN FD
    CAN XL
    Channels





    Transmission
    Transmitting messages in layer 2 format via broadcasting lists (one-off/cyclic) Transmit
    Transmitting sequences in layer 2 format to emulate CAN-nodes Transmit  
    Reception and display
    Display received messages
    - Scroll view
    - Overwrite mode
    Receive



    Filtering during reception or recording Filter  
    Symbolic representation via Symbol files Symbol  
    Symbolic aditor Symbol  
    Symbolic import from CANdb Import or AUTOSAR XML CANdb add-in  
    Recording/Playback
    Recording on hard disk
    - Maximum size
    Record
    1 GB

    Filter and trigger functions during recording Filter  
    Playback of recordings on the buses for analyzing Replay  
    Playback break pints and single step Replay  
    Workflow management
    Project and task management Workflow   Phyton
    VBScript
    Automation of tasks Automation   Phyton
    VBScript
    Take actions triggered by CAN Automation   Phyton
    VBScript
    J1939 Support
    Display of J19839 and J1939 FD messages J1939 Add-in  
    Adresclaiming, Multi-packet or DTC's J1939 Add-in  
    Configurable Display of Signal Curves
    Graphical real-time display of signals Plotter Add-in  
    Display of limiting values and value ranges Plotter Add-in  
    Signal Display and Manipulation
    Representation of analog and digital signals with displays Panel Add-in  
    Adding controls to manipulate transmit messages Panel Add-in  
  • Does this interface support CANopen or J1939?

    Yes, the PCAN-USB X6 works with all CAN messages, including CANopen and J1939

    However, the CAN messages are not interpreted as CANopen or J1939. Separate software is available for generating or interpreting CANopen or J1939. Please enquire about the options.

  • Can I order on account?

    Yes, that's definitely possible! Most customers place their orders through a Purchase Order.
    First request a quote and then send the purchase order (PO) by email, simply from your own purchasing system. For first time buyers, we may ask additional questions in order to perform a credit check. Please contact us if you require our company details for registration in the purchasing system.

    For security reasons, customers located in, or wishing to ship to, countries outside the Benelux must always pay in advance.

  • Why are all prices available upon request?

    The online webshop is still under construction. As soon as it is available, all prices will naturally be visible.

    However, everything is of course available, and we would be happy to inform you about prices and delivery times. Please contact us or give us a call. We have over 30 years of experience with CAN. We are happy to help you and offer you immediate practical advice or support.

 

Part number(s)

IPEH-004062 PCAN-USB X6
6x CAN FD, Galvanic Isolation
Country of Origin: Germany
HS Code: 8517620000
IPEH-004063 PCAN-USB X6
6x CAN FD, Galvanic Isolation
Country of Origin: Germany
HS Code: 8517620000
IPEH-004064 PCAN-USB X6
6x CAN FD, Galvanic Isolation
Country of Origin: Germany
HS Code: 8517620000

Scope of Supply

PCAN-USB X6
  • User Manual 1
  • Peak Driver voor Windows® 11 (x64/ARM64)
  • Bus-monitor "PCAN-View" for CAN FD and CAN (Windows®) 2
  • Programming interface and API "PCAN-Basic" for developing CAN applications 2
1 Available as PDF
2 All software available by download

Interested?

Are you interested in the PCAN-USB X6? Request a quote without obligation. Would you like more information? Send an email to -Hidden- or visit our contact page. You can also call us at -Hidden-.
Twincomm has over 30 years of experience with CAN. We are happy to help you and offer you immediate practical advice or support.