The CAN specialist
-Hidden- -Hidden-
Nederlandse taal English language
Skip to main content

canAnalyser 3 – J1939

J1939 protocol module for canAnalyser 3

 

 
 
The Ixxat canAnalyser 3 – J1939 supports the J1939 protocol
canAnalyser 3 – J1939by Ixxat

Request for quote

Ask a question

By default, the Ixxat canAnalyser 3 – J1939 interprets all received messages according to the SAE J1939 notation. First, this includes the interpretation of received J1939 messages and relevant network data. In addition, the module automatically interprets the Parameter Group Number, source address, and destination address. Furthermore, transmitted Suspect Parameters are displayed with their name, value, and unit. During analyses, the software also displays the message priority and Data Page information. Furthermore, the Protocol Data Unit Format and specific PDU fields are clearly displayed on the screen. This provides quick insight into complex vehicle communication. In short, the module significantly simplifies comprehensive J1939 diagnostics and network monitoring.

The canAnalyser 3 – J1939 automatically translates raw CAN messages into understandable J1939 parameters, such as PGNs and SPNs. This gives users immediate insight into vehicle data and system behavior. Moreover, manual interpretation of hexadecimal data is usually no longer necessary. For example, during vehicle diagnostics, error messages are recognized and analyzed more quickly. In addition, the module supports efficient analysis of heavy-duty vehicles and industrial applications. Because all relevant communication is clearly displayed, diagnostics are faster and more accurate. In summary, the canAnalyser 3 – J1939 offers a powerful solution for professional SAE J1939 analysis.


Features and benefits

  • Simplifies the analysis of SAE J1939 networks and devices
  • Direct display of all SAE J1939 messages according to the CANopen specification
  • Full and easy integration into the canAnalyser environment

J1939 Module

J1939 Module

The J1939 module allows the processing and interpretation of the J1939 transport protocol as well as the interpretation of diagnostic messages. Proprietary application messages can be interpreted if a user defined database with Parameter Group and Suspect Parameter definitions is provided. Such a database can be e.g. a XML file generated by the Ixxat SAE J1939 Designer.

To clearly arrange displayed J1939 messages, it is possible to set filters for Parameter Group Numbers as well as Source and Destination Addresses. Processing/documentation of the received messages can be made permanent or on command by a CSV export to an ASCII file.

FAQ

  • Which Ixxat CAN analysis software is best suited to my use case?

    The canAnalyser is a versatile analysis tool for the development, testing and servicing of CAN, CAN FD and LIN based systems. The software package is based on a modular concept and available in three versions - Mini, Lite, and Standard - with a different set of functions and modules.
    The Mini version is included free of charge with the VCI driver. It is ideal for quick diagnostics or hardware testing, for example. The Lite and Standard versions are both comprehensive, professional software packages designed for development, debugging, simulation, or testing of CAN, CAN FD and/or LIN-networks.

    Each version of the canAnalyser 3 is intended for typical use case. The table below provides a handy overview of all the differences.

    Functions Module canAnalyser3
    Mini
    canAnalyser 3
    Lite
    canAnalyser 3
    Standard
    Measurement configuration
    Supported bus controllers   1 1 64
    Number of function modules per bus controller (multi-start)   1 1 per function
    Transmission
    Transmitting messages in layer 2 format via broadcasting lists (one-off/cyclic) Transmit Max 5
    Transmitting signals based on underlayed databases Signal/Transmit    
    Transmitting sequences in layer 2 format using simple commands for control Sequencer  
    Reception and display
    Display received messages
    - Scroll view
    - Overwrite mode
    Receive




    Filtering during reception Receive  
    Signal reception and interpreted online display based on databases (overwrite/scroll) Signal   Max 5
    Graphical display of received signals over the time axis Signal   Max 5
    Display of statistical values (e.g. bus load, number of error frames) Signal  
    Logging of value range overflows Signal  
    Graphical display of frequency distribution of received messages Histogram  
    Recording/Playback
    Recording on hard disk
    - Maximum size
    Trace
    1 GB


    Filter and trigger functions during recording Trace  
    Recording on hard disk for later analysis, including filter and trigger functions Trace  
    Playback of recordings on the buses and/or modules for analyzing Replay  
    Adaptation and Extension
    Development of measurement/analysis functions using C# and Visual-Basic .NET scripts Scripting/Host  
    Open interface for expansion by customer-specific modules (.NET modules) customized  
    Protocol Interpreter
    Display of CANopen messages according to CANopen specification CANopen  
    Display of SAE J1939 messages according to SAE J1939 specification J1939  
  • Does canAnalyser 3 support CANopen or J1939?

    Yes, both the canAnalyser 3 Lite and Standard come with modules for interpreting CANopen and J1939 messages. Both protocols can be supplemented with user-defined databases. CANopen FD and J1939 FD are not supported.

  • Can I order on account?

    Yes, that's definitely possible! Most customers place their orders through a Purchase Order.
    First request a quote and then send the purchase order (PO) by email, simply from your own purchasing system. For first time buyers, we may ask additional questions in order to perform a credit check. Please contact us if you require our company details for registration in the purchasing system.

    For security reasons, customers located in, or wishing to ship to, countries outside the Benelux must always pay in advance.

  • Why are all prices available upon request?

    The online webshop is still under construction. As soon as it is available, all prices will naturally be visible.

    However, everything is of course available, and we would be happy to inform you about prices and delivery times. Please contact us or give us a call. We have over 30 years of experience with CAN. We are happy to help you and offer you immediate practical advice or support.

 

Part number(s)

1.12.0149.30000 canAnalyser 3 – J1939
Country of Origin: Germany
HS Code: 8473302000

System requirements

  • Windows® (x32) 7, 8, 10 or 11
  • canAnalyser 3 with matching license

Interested?

Are you interested in the canAnalyser 3 – J1939? Request a quote without obligation. Would you like more information? Send an email to -Hidden- or visit our contact page. You can also call us at -Hidden-.
Twincomm has over 30 years of experience with CAN. We are happy to help you and offer you immediate practical advice or support.